Table 3. Data of 10 significant mechanical fractures.
Gender | Age | Position | Bone graft | Implant length | Diameter | Preceding screw loosening | Fracture site | Re-restoration | Periods (months) | Para-functional habit or dental status | |
---|---|---|---|---|---|---|---|---|---|---|---|
1 | Female | 54 | 37 | No | 8 mm | 4.5 mm | No | Abutment neck with screw | Yes | 20 | Attrition |
2 | Female | 48 | 46 | No | 8 mm | 5.5 mm | Yes | Abutment neck with screw | Yes | 26 | |
3 | Male | 49 | 46 | No | 11 mm | 4.5 mm | Yes | Abutment neck with screw | No | 29 | Attrition |
4 | Male | 47 | 12 | No | 11 mm | 3.5 mm | Yes | Abutment neck with screw, Porceline | Yes | 32 | |
5 | Male | 58 | 17 | Yes | 8 mm | 4.5 mm | No | Abutment neck with screw | No | 33 | |
6 | Male | 49 | 26 | Yes | 11 mm | 4.5 mm | No | Abutment neck with screw | No | 38 | |
7 | Male | 47 | 47 | No | 9.5 mm | 5.5 mm | No | Abutment neck with screw | No | 51 | |
8 | Male | 56 | 37 | No | 9.5 mm | 4.5 mm | No | Abutment neck with screw | Yes | 77 | |
9 | Male | 42 | 26 | No | 11 mm | 4.5 mm | Yes | Abutment neck with screw | Yes | 84 | Bruxism |
10 | Male | 42 | 17 | No | 14 mm | 4.5 mm | No | Abutment neck with screw | Yes | 37 |