Skip to main content
. 2016 Jan 22;11(1):e0147159. doi: 10.1371/journal.pone.0147159

Table 1. Terms introduced to simulate different dialysis timeframes using our calibrated kinetic models.

Strategy TT/week(h) BV/week(L) QB(mL/min) QD(mL/min) QUF ER(%)
3x4h_300/w 12 216 300 700 a.m.* a.m.*
3x8h_150/w 24 216 150 700 a.m.*/2 a.m.* x 1.33 (urea) [40]
a.m.* x 1.00 (PBS) [41]
6x2h_300/w 12 216 300 700 a.m.* a.m.*
6x4h_150/w 24 216 150 700 a.m.*/2 a.m.* x 1.33 (urea) [40]
a.m.* x 1.00 (PBS) [41]
3x8h_300/w 24 432 300 700 a.m.*/2 a.m.*
6x4h_300/w 24 432 300 700 a.m.*/2 a.m.*
6x8h_150/w 48 432 150 700 a.m.*/4 a.m.* x 1.33 (urea) [40]
a.m.* x 1.00 (PBS) [41]

3x4h_300/w: thrice weekly 4 h dialysis with QB300; 3x8h_150/w: thrice weekly extended (8 h) dialysis with QB150; 6x2h_300/w: frequent (6 times) short (2h) dialysis with blood flow QB300; 6x4h_150/w: frequent 4 h dialysis with QB150; 3x8h_300/w thrice weekly extended dialysis with QB300; 6x4h_300/w: frequent 4 h dialysis with QB300; 6x8h_150/w: frequent extended dialysis with QB150. TT: treatment time; BV: processed blood volume; ER: extraction ratio; PBS: protein-bound solutes

a.m.*: as measured in the present kinetic study during 4 h dialysis