Image quality scores for each reader and each sequence (mean ± standard deviation)

Sequence/parameter Radial-VIBE
Ax magnetization-prepared gradient echo
Ax FS T1W
Cor FS T1W
Cor Radial-VIBE
Reader 1 Reader 2 Reader 1 Reader 2 Reader 1 Reader 2 Reader 1 Reader 2 Reader 1 Reader 2
Motion artefact 5.00 ± 0 4.91 ± 0.29 3.98 ± 0.65 3.72 ± 0.72 4.07 ± 0.73 3.93 ± 0.62 4.59 ± 0.56 4.31 ± 0.54 5.0 ± 0 4.97 ± 0.18
Degree of fat suppression 4.65 ± 0.8 4.63 ± 0.71 3.8 ± 1.00 3.59 ± 0.78 3.29 ± 0.91 3.5 ± 1.02 3.81 ± 0.64 3.81 ± 0.59 4.78 ± 0.42 4.78 ± 0.49
Clarity of choroidal enhancement 5.00 ± 0 4.96 ± 0.21 4.76 ± 0.43 4.3 ± 0.7 4.14 ± 0.86 4.0 ± 0.78 3.72 ± 0.52 3.94 ± 0.76 5.0 ± 0 4.97 ± 0.18
Clarity of the vessel 4.89 ± 0.32 4.93 ± 0.25 3.52 ± 0.66 3.83 ± 0.61 2.79 ± 0.43 3.14 ± 0.66 3.0 ± 0.36 3.41 ± 0.71 4.84 ± 0.37 4.97 ± 0.18
Clarity of the muscle 4.98 ± 0.15 4.89 ± 0.32 4.22 ± 0.79 4.13 ± 0.78 4.57 ± 0.51 4.07 ± 0.73 4.44 ± 0.67 4.22 ± 0.49 5.0 ± 0 4.94 ± 0.25
Clarity of optic nerve 5.00 ± 0 4.85 ± 0.36 3.76 ± 0.9 3.7 ± 0.84 2.64 ± 0.63 3.36 ± 0.75 3.38 ± 0.71 3.53 ± 0.67 5.0 ± 0 4.91 ± 0.3
Clarity of brain parenchyma 4.67 ± 0.47 4.33 ± 0.52 4.87 ± 0.34 4.35 ± 0.6 2.21 ± 0.58 2.29 ± 0.47 2.16 ± 0.37 2.38 ± 0.49 4.72 ± 0.46 4.5 ± 0.57
Conspicuity of pathology 4.71 ± 0.85 4.74 ± 0.53 3.96 ± 1.07 3.86 ± 0.89 3.6 ± 1.08 3.4 ± 0.7 3.22 ± 1.17 3.67 ± 0.77 4.67 ± 0.97 4.61 ± 0.98