Table 7.

Estimates of apparent diffusion coefficient values reported in human Uterus (endometrium, myometrium and cervix) using a mono-exponential fit

Ref. System Field strength (T) Sequence TR/TE (ms/ms) No. of patients/mean age (SD) b-values (s/mm2) Mean ADC (SD) (× 10-3 mm2/s)
Naganawa et al[99], 2005 Siemens Symphony 1.5 SS SE EPI 2500/96 10/46.6 0, 300, 600 Cervix, 1.79 (0.24)
Tamai et al[88], 2007 Siemens Symphony 1.5 SS SE EPI, FS 4400/(74-99) 12/49 0, 500, 100 Endometrium, 1.53 (0.10)
Zhang et al[176], 2007 Philips Intera 1.5 SS SE EPI 6800/70 (9 + 7V)/34 median 0, 800 Cervix, 1.71 (0.14)
McVeigh et al[91], 2008 GE Signa 1.5 SS SE EPI 4000/68 30/47 0, 600 Cervix n = 26, 2.09 (0.46)
Shen et al[92], 2008 GE Excite 1.5 SS SE EPI 8000/83 7/45.2 0, 500, 800, 1000 Endometrium, 1.277 (0.219)
Fujii et al[177], 2008 Siemens Symphony 1.5 SS SE EPI, STIR FS, FB (9500-9800)/(73-78) 26/53 0, 1000 Endometrium n = 25, 1.44 (0.34)
Tamai et al[89], 2008 Siemens Symphony 1.5 SS SE EPI, FS (2700-4400)/(78-90) 43/48 0, 500, 1000 Myometrium, 1.62 (0.11)
Inada et al[178], 2009 GE Signa 1.5 SS SE EPI, FB (3400-7500)/68 31/44.9 (12.7) 0, 800 Endometrium, 1.52 (0.20)
Myometrium, 1.53 (0.25)
Liu et al[179], 2009 GE Excite 1.5 SS EPI 4000/58.5 57 0, 1000 Cervix, 1.50 (0.16)
Payne et al[180], 2010 Philips Intera 1.5 SS SE EPI 4500/80 62/38 0, 100, 300, 500, 800 Cervix n = 43, 1.769 (0.239)
Chen et al[98], 2010 Philips Intera 1.5 SS SE EPI, STIR FS 6800/70 20/34.4 0, 800 Cervix, 1.593 (0.151)
Cao et al[87], 2012 GE Signa 1.5 SS SE EPI, FB NR/NR 64/55.4 0, 1000 Endometrium, 1.267 (0.221)
Myometrium, 1.496 (0.196)
Junctional zone, 1.126 (0.190)
Kuang et al[90], 2013 Siemens Trio 3.0 SS SE EPI, FS AX: 7000/71, 67 (1) 0, 600 Cervix, (1) 1.55 (0.28)
SAG: 1800/76 (2) 0, 1000 (2) 1.41 (0.10)

Some studies were carried out with more b-values than specified in the following table to compute intravoxel incoherent motion-specific parameters. ADC: Apparent diffusion coefficient; NR: Not reported; SS: Single shot; SE: Spin echo; EPI: Echo planar imaging; RF: Radiofrequency; RT: Respiratory triggered; NC: Navigator controlled; FB: Free breathing; BH: Breath-hold; BHI: Breath-hold end inspiratory; BHE: Breath-hold end expiratory; n: Number of patients; STIR: Short TI inversion recovery; FS: Fat suppression; NA: Not available; AX: Axial; SAG: Sagittal; W: Week; V: Volunteer.