Skip to main content
. 2016 Jan 28;8(1):21–49. doi: 10.4329/wjr.v8.i1.21

Table 8.

Estimates of apparent diffusion coefficient values reported in the normal fibroglandular breast tissue using a mono-exponential fit

Ref. System Field strength (T) Sequence TR/TE (ms/ms) No. of patients/mean age (SD) b-values (s/mm2) Mean ADC (SD) (× 10-3 mm2/s)
Englander et al[181], 1997 GE Signa 1.5 SE (2 or 3)HB/100 4/32 (2.6) 12.48, 611.31, 199.61, 449.12, 77.97, 311.89, 112.28 1.64 (0.19)
Partridge et al[17], 2001 GE Signa 1.5 SS FSE 8000/86 8/27 0, 578 n = 6, W1: 1.72 (0.23) W2: 1.61 (0.22) W3: 1.66 (0.17) W4: 1.75 (0.17)
Sinha et al[105], 2002 GE Signa 1.5 SS EPI 5000/72 16 0, 269, 537, 806, 1074 2.37 (0.27)
Woodhamset al[106], 2005 GE Signa 1.5 SS SE EPI 5000/61.8 190/53 0, 750, 1000 2.09 (0.27)
Park et al[182], 2007 GE Signa 1.5 SS EPI 6000/75 41/53.1 0, 1000 1.51 (0.29)
Yoshikawa et al[107], 2008 Philips Intera 1.5 SS SE EPI 6238/90 27 0, 200, 400, 600, 800 1.96 (0.21)
Kim et al[119], 2009 GE Signa 1.5 SS SE EPI 6000/75 67/54 0, 1000 1.59 (0.27)
Baron et al[114], 2010 Siemens Avanto 1.5 SS SE EPI, (1) FS (2) STIR (3) SPAIR (4) WaterExcitation 3000/93 7/26.6 0, 20, 40, 60, 80, 100, 150, 200, 300, 400, 500, 600 (1) 1.99 (2) 2.02 (3) 2.03 (4) 2.06 overall 2.03 (0.03)
Partridge et al[44], 2010 GE Signa 1.5 SS SE EPI 7 s/71.5 12/36 (median) 0, 600, 1000 1.95 (0.24)
O’Flynn et al[109], 2012 Philips Achieva 3.0 SS SE EPI, SPAIR, SSGR 3771/67 31/45.9 13 PRM/36.6 18 PM/55.2 (1) 0, 100, 150, 200, 350, 700, 1200 (2) 100, 150, 200, 350, 700, 1200 PRM, (1) 1.84 (0.26) (2) 1.77 (0.26) PM, (1) 1.46 (0.3) (2) 1.33 (0.3)
Tagliafico et al[183], 2012 GE Signa 3.0 SS EPI 16675/NR 60/57 (median) 0, 1000 1.92 (0.30)
AlRashidi et al[108], 2012 Philips Achieva 3.0 SS SE EPI, SPAIR 9543/50 26 0, 50, 150, 800 MC, W1: 2.18 (0.38) W2: 2.20 (0.39) W3: 2.22 (0.38) W4: 2.22 (0.33)
McDonald et al[184], 2014 Philips Achieva 3.0 SS SE EPI 5336/61 103/47 (11) 0, 800 1.62 (0.30)

Some studies were carried out with more b-values than specified in the following table to compute intravoxel incoherent motion-specific parameters. ADC: Apparent diffusion coefficient; F: Female; M: Male; NR: Not reported; SS: Single shot; SE: Spin echo; EPI: Echo planar imaging; FSE: Fast spin echo; RF: Radiofrequency; RT: Respiratory triggered; NC: Navigator controlled; FB: Free breathing; BH: Breath-hold; HB: Heart beats; n: Number of patients; SPAIR: Spectral selection attenuated inversion recovery; SSGR: Slice selection gradient reversal; FS: Fat suppression; AX: Axial; SAG: Sagittal; MC: Menstrual cycle; PM: Post-menopause; PRM: Pre-menopause; W: Week; L: Left; R: Right.