Skip to main content
. 2015 Dec 15;192(12):1504–1513. doi: 10.1164/rccm.201501-0053OC

Figure 10.

Figure 10.

Associations between laryngeal (A), subglottic (B), and tracheal (C) airway wall thickness (y-axis) and total duration of intubation plotted on a logarithmic scale (x-axis). Data points represent mean measurements from 48 long-range optical coherence tomography cases. Linear regression lines (dashed line) are plotted at the mean patient weight.