Skip to main content
. 2015 Dec 28;16(1):34. doi: 10.3390/s16010034

Table 5.

The accuracy of FDT and contrast PDR system.

Field User SONY Z2 SONY Z3 HTC M7
PDR FDT PDR FDT PDR FDT
NCKU A 12.07 0.61 29.96 0.66 2.43 1.09
143 m B 14.00 0.66 33.44 0.68 1.30 0.74
C 12.45 0.60 32.90 0.64 0.91 0.64
D 9.40 0.61 30.42 0.77 5.79 0.66
III A 3.19 0.89 1.84 3.86 1.28 0.93
162 m B 1.98 0.99 3.28 1.33 0.78 0.61
C 4.48 0.86 7.12 1.19 1.14 1.16
D 5.07 1.17 1.71 0.87 4.36 3.87
Enterprise A 3.47 3.39 6.99 1.66 13.03 0.54
175 m B 9.91 2.31 3.47 0.89 11.12 1.19
C 3.02 1.75 1.48 1.94 7.98 0.82
D 2.59 3.38 2.53 1.71 8.79 1.25
Mean of FDT: 1.3, Standard deviation: 0.94
: Mean of contrast PDR: 8.21, Standard deviation: 9.26
Unit: loop closure error/travelling distance (%)