Skip to main content
. 2016 Jan 9;11:46–51. doi: 10.1016/j.nicl.2016.01.002

Table 5.

Moderate AD versus controls classification. Multimodal represents the best combination from step 5 of our stepwise multimodal procedure (GMD, FA, WMD, PC, and MD).

Modality AUC Min–max Sensitivity Specificity Accuracy
GMD 0.933 (0.924–0.942) 0.777 0.941 0.912
WMD 0.860 (0.853–0.866) 0.515 0.936 0.860
FA 0.794 (0.787–0.804) 0.361 0.978 0.867
MD 0.826 (0.811–0.839) 0.447 0.974 0.879
COR 0.793 (0.769–0.823) 0.465 0.944 0.858
SPC 0.812 (0.795–0.829) 0.349 0.956 0.847
Multimodal 0.971 (0.964–0.975) 0.813 0.956 0.930