Table 3.
Grip strength values
| T0 | T+5 | Change | P-value | ||
|---|---|---|---|---|---|
| Dominant | PT [mean (std)] | 37.8 (9.6) | 36.7 (10.1) | -1.1 (0.5) [-2.96%] | P =0.183 |
| SRT [mean (std)] | 39.3 (10.3) | 37.0 (10.6) | -2.3 (0.3) [-5.7%] | P =0.049* | |
| Non-Dominant | PT [mean (std)] | 35.3 (8.3) | 36.0 (9.0) | 0.7 (0.7) [+0.83%] | P =0.405 |
| SRT [mean (std)] | 38.7 (10.2) | 36.3 (9.0) | -2.4 (1.2) [-3.88%] | P =0.002* |
T0: Time 0. Grip strength measurement before the tourniquet application.
T5: Time 5. Grip strength measurement five (5) minutes after the tourniquet removal.
P<0.05. Statistically significant difference