Skip to main content
. 2015 Jun 5;128(11):1421–1427. doi: 10.4103/0366-6999.157626

Table 4.

Recruited and over-distended pixels changed with PEEP titration between two groups

Groups Recruited pixels Over-distended pixels
Nonresponders
 PEEP 20 (n = 4) 46 (30–79) 26 (15–83)
 PEEP 17 (n = 4) 47 (29–67) 27 (10–97)
 PEEP 14 (n = 5) 31 (22–103) 29 (6–71)
 PEEP 11 (n = 5) 33 (20–93) 37 (7–63)
 PEEP 8 (n = 4) 34 (19–80) 40 (15–61)
 PEEP 5 (n = 4) 44 (23–69) 37 (25–44)
Responders
 PEEP 20 (n = 11) 82 (66–127) 26 (15–83)
 PEEP 17 (n = 13) 86 (56–121) 37 (19–80)
 PEEP 14 (n = 13) 76 (46–107)* 38 (10–65)
 PEEP 11 (n = 12) 80 (52–101) 17 (5–54)†‡
 PEEP 8 (n = 11) 84 (73–116) 5 (3–35)†‡
 PEEP 5 (n = 9) 51 (33–77) 8 (3–46)

*P < 0.05, compared with PEEP 20 in the same group; P < 0.05, compared with the neighboring upper PEEP in the same group; P < 0.01, compared with PEEP 20 in the same group. PEEP: Positive-end expiratory pressure.