Skip to main content
. Author manuscript; available in PMC: 2017 Jan 15.
Published in final edited form as: Int J Cardiol. 2015 Nov 11;203:848–854. doi: 10.1016/j.ijcard.2015.11.073

Table 3.

Native myocardial T1 time in each slice levels

Base Mid Apex +P value between slices
AF patients, n=50 1093 ± 72 1100 ± 65 1109 ± 66 0.51
Control subjects, n=11 1035 ± 25 1037 ± 32 1060 ± 25 0.075
*P value (AF vs controls) 0.010 0.003 0.018

Values are presented as mean ± SD.

+

P-values represent significance of difference between 3 slices (base, mid and apex) both in AF patients and controls (one way analysis of variance with Tukey’s correction).

*

P-values represent significance of difference between AF patients and controls in base, mid and apex.

AF, atrial fibrillation