Skip to main content
. Author manuscript; available in PMC: 2017 Jan 15.
Published in final edited form as: Int J Cardiol. 2015 Nov 11;203:848–854. doi: 10.1016/j.ijcard.2015.11.073

Table 5.

Reproducibility of native T1 measurement in AF patients and healthy controls

10 healthy controls 10 AF subjects
Intra-observer reproducibility Inter-observer reproducibility Intra-observer reproducibility Inter-observer reproducibility
Repeatability coefficient 25msec 27msec 40msec 46msec
Intra class correlation coefficient 0.96 (95%CI: 0.85–0.99, p<0.05) 0.95 (95%CI: 0.80–0.99, p<0.05) 0.92 (95%CI: 0.87–0.95, p<0.05) 0.91 (95%CI: 0.86–0.94, p<0.05)
Coefficient of Variation 0.8% 1.1% 1.4% 1.6%

AF, atrial fibrillation; CI, confidence interval

Repeatability coefficients were calculated as 1.96 times the standard deviation of the differences on the Bland-Altman plots.