Skip to main content
. 2015 Oct 12;60(2):205–219. doi: 10.1093/annhyg/mev074

Table 1.

Summary of geometric mean (GM) and geometric standard deviation (GSD), range and coefficient of variation (CV) of particle number concentration (PNC) and geometric mean diameter (GMD) of SMPS and DiscMini at the near-field (NF) and breathing zone (BZ). Data from the DiscMini at both BZ and NF station were available for all 20 volunteers, while SMPS data was available for 19 volunteers due to instrument malfunction for one volunteer.

SMPS (NF) DiscMini 1 (NF) DiscMini 2 (BZ)
Number of valid observations 19 20 20
PNC (particles cm−3)
 GM of PNC 7.74E+05 1.10E+06 1.69E+06
 GSD 1.6 1.86 2.42
 PNC Min 2.70E+05 5.23E+05 8.69E+05
 PNC Max 1.28E+06 2.89E+06 3.85E+06
 CV 60% 86% 142%
Size (nm)
 GMD 69 51 45
 GSD 1.89 1.48 1.61
 GMD Min 32 32 29
 GMD Max 170 112 108
 CV 89% 48% 61%