Table 2. Observations and comparison among commercial software packages and our proposed method.

  Method 1: Using the Imageware, UG, and Magics RP togther Method 2: Using 3-matic (Materialise, Leuven, Belgium) Method 3: Using TemDesigner
Oral implantology Time(h) 2-3 1-2 0.2-0.3
User interaction Very Complicated Complicated Simple and Easy
Required user experience Very High High Low
Iliosacral screw insertion Time(h) 1-2 0.5-1 0.2-0.3
User interaction Very Complicated Complicated Simple and Easy
Required user experience Very High Medium Low
Cervical pedicle screw placement Time(h) 2-3 1-2 0.2-0.3
User interaction Very Complicated Complicated Simple and Easy
Required user experience Very High High Low
Osteotomy Time(h) 0.5-1 0.5-1 0.2
User interaction Very Complicated Complicated Simple and Easy
Required user experience Very High Medium Low