Skip to main content
. 2016 Feb 11;11(2):e0148709. doi: 10.1371/journal.pone.0148709

Table 2. Diagnostic performance of GDF-15 (A) and FGF-21 (B) for a cut-off value of 550pg/ml and 300pg/ml respectively.

95% confidence intervals are indicated in brackets.

GDF-15
Group Sensitivity Specificity PPV NPV
All 67.8%(54.4%–79.4%) 92.3%(81.5%–97.9%) 93% (80.9%–98.5%) 61.2% (46.2%–74.8%)
Confirmed 72.7% (49.8%–89.2%) 92.3% (81.5%–97.9%) 84.2%(60.4%–96.6%) 83.3%(67.2%–93.6%)
Definitive 70% (45.7%–88.1%) 92.3% (81.5%–97.9%) 82.3%(56.7%–96.2%) 83.3%(67.2%–93.6%)
Probable 58.8%(32.9%–81.6%) 92.3% (81.5%–97.9%) 76.9%(46.2%–94.9%) 81.1% (64.8%–92%)
FGF-21
Group Sensitivity Specificity PPV NPV
All 52.5% (39.1%–65.7%) 96.2%(87%–99.5%) 100% (89.4%–100%) 56.7% (43.2%–69.4%)
Confirmed 59.1% (36.3% to 79.3%) 96.2%(87%–99.5%) 100% (78.2%–100%) 82.9% (67.9%–92.8%)
Definitive 60%(36.1%–80.9%) 96.2%(87%–99.5%) 100% (73.5%–100%) 80.9%(56.9%–91.4%)
Probable 35.3% (14.2%–61.7%) 96.2%(87%–99.5%) 100% (54.1%–100%) 75.6% (60.5%–87.1%)