TABLE II.

Summary of the dosimetric results for the planning target volumes

Parameter (A) 3D-CRT (B) IMRT (C) RapidArca p Valueb

A vs. B A vs. C B vs. C
V95% (%) 99.70±0.41 99.96±0.04 99.97±0.04 0.046 0.046 0.707
V110% (%) 8.56±5.24 0.46±0.29 0.23±0.18 0.001 0.001 0.382
Dmax (Gy) 56.43±0.45 56.08±0.48 56.37±0.85 0.210 0.816 0.371
Dmean (Gy) 53.61±0.29 52.99±0.24 53.05±0.01 0.001 0.000 0.409
Conformity index 0.72±0.06 0.84±0.03 0.88±0.05 0.000 0.001 0.036
Homogeneity index 1.09±0.01 1.07±0.01 1.06±0.01 0.001 0.000 0.120
Monitor units 290.4±18.93 630.02±62.14 565.07±76.12 0.000 0.000 0.028
Delivery time (min) 0.97±0.06 2.10±0.21 1.05±0.10 0.000 0.095 0.000
a

Varian Medical Systems, Palo Alto, CA, U.S.A.

b

By paired t-test analysis.

3D-CRT = 3-dimensional conformal radiotherapy; IMRT = intensity-modulated radiotherapy; Vx% = volume receiving x% or more of the prescribed dose; Dmax = maximum dose to the organ; Dmean = mean dose to the organ.