Table 3.

Sleep and arrhythmia parameters in subgroups prior to and following the application of CPAP therapy

Variable AHI < 10 (n = 10) AHI ≥ 10 (n = 41) p-value*
Pressure (cm H2O) 8.07 ± 0.15 8.29 ± 3.50 0.647
Compliance (h/night) 4.7 ± 2.5 5.8 ± 3.1 0.307
Pre-CPAP Post-CPAP p-value** Pre-CPAP Post-CPAP p-value**
Mean O2 desaturation (%) 8 % 7 % 0.506 23 % 7 % 0.047
AHI (events/h) 5.28 ± 1.25 3.53 ± 0.35 0.189 41.01 ± 24.20 3.93 ± 2.58 0.014
RR interval(>2 s, events/h) 30.67 ± 38.66 35.33 ± 48.34 0.051 110.89 ± 299.27 16.07 ± 58.52 0.001
Longest RR (>2 s, second) 2.68 ± 1.12 2.6 ± 0.58 0.952 13.81 ± 50.29 0.53 ± 1.00 0.058

Values are given as mean ± SD and n %

*Comparison of CPAP parameters between two subgroups at an AHI cut-off point of 10

**Comparison of changes in the sleep and arrhythmia variables at baseline and after CPAP in two subgroups