Skip to main content
. 2015 Dec;35(6):433–441. doi: 10.14639/0392-100X-619

Table V.

Correlation of differences between post- and pre-operative hearing thresholds and type of cochleostomy (Median, IQR).

Frequency Fenestral (n=12) Promontorial (n=143) p value
Average 11 (7-18) 12 (6-20) 1
0.5 kHz 20 (12-27) 15 (7-30) 0.5
1 kHz 10 (5-20) 10 (5-20) 0.7
2 kHz 5 (0-22) 10 (5-20) 0.5
4 kHz 5 (0-12) 5 (5-15) 0.3