Table 2. Estimated detection rates for daily snapshot monitoring in patients with stroke risk factors.

Monitoring window of simulated daily snapshots Number of patients with CIED data in window Number of AT/AF patients detected by CIED in window (%) Number of AT/AF patients detected by snapshot monitoring
% of total patients % of patients with AT/AF in window
Primary analysis (n = 370)
14 days 370 92 (24.9 [20.5–29.6]%) 37/370 (10.0 [7.1–13.5]%) 37/92 (40.2 [30.1–51.0]%)
28 days 366 122 (33.3 [28.5–38.4]%) 54/366 (14.8 [11.3–18.8]%) 54/122 (44.3 [35.3–53.5]%)
56 days 359 166 (46.2 [41.0–51.5]%) 77/359 (21.4 [17.3–26.1]%) 77/166 (46.4 [38.6–54.3]%)
112 days 351 229 (65.2 [60.0–70.2]%) 99/351 (28.2 [23.6–33.2]%) 99/229 (43.2 [36.7–49.9]%)
365 days 254 254 (100.0%) 126/254 (49.6 [43.3–55.9]%) 126/254 (49.6 [43.3–55.9]%)
Secondary analysis (n = 526)
14 days 526 146 (27.8 [24.0–31.8]%) 77/526 (14.6 [11.7–18.0]%) 77/146 (52.7 [44.3–61.1]%)
28 days 521 189 (36.3 [32.1–40.6]%) 104/521 (20.0 [16.6–23.7]%) 104/189 (55.0 [47.6–62.3]%)
56 days 510 252 (49.4 [45.0–53.8]%) 135/510 (26.5 [22.7–30.5]%) 135/252 (53.6 [47.2–59.9]%)
112 days 496 327 (65.9 [61.6–70.1]%) 165/496 (33.3 [29.1–37.6]%) 165/327 (50.5 [44.9–56.0]%)
365 days 363 363 (100.0%) 203/363 (55.9 [50.6–61.1]%) 203/363 (55.9 [50.6–61.1]%)

Primary analysis was conducted for 370 patients, excluding those who were taking warfarin or antiarrhythmic drugs at baseline; secondary analysis was conducted for 526 patients, including those who were taking warfarin or antiarrhythmic drugs at baseline. Data are expressed as means [95% confidence intervals] of estimated AT/AF detection rates with the snapshot monitoring. CIED indicates cardiac implantable electronic device; AT, atrial tachycardia; AF, atrial fibrillation.