Skip to main content
. 2016 Jan 27;113(6):E715–E724. doi: 10.1073/pnas.1515730113

Table 1.

Comparison of fitting parameter sets for two different models for the rates obtained in our simulations and rates from the SMFS experiment (16)

Simulations Experiment
Name Value Error Units Value Error Units
kL0 1.5 0.4 Seconds−1 2.0 1.1 102 s−1
kH0 3.9 10.0 103 s−1 6.1 6.4 106 s−1
xL 0.40 0.1 Nanometers 0.08 0.1 Nanometers
xH 1.16 0.3 Nanometers 1.42 0.12 Nanometers
P2/P1103 P2/P11017

The definition of P2/P1 is given in Materials and Methods. The errors come out of log-likelihood covariance matrix with respect to parameters.