Skip to main content
. 2015 Oct 6;31(3):297–303. doi: 10.1007/s11606-015-3514-0

Table 3.

Comparison of Test Characteristics for 3D-CAM and CAM-ICU Stratified by Baseline Cognition (Normal/MCI vs. Dementia)

Test Characteristics in Patients with Normal Cognition/MCI at Baseline (N = 75)
3D-CAM
 Sensitivity (%) 6/6 (100 %)
 95 % CI [54 %,100 %]
 Specificity (%) 66/69 (96 %)
 95 % CI [88 %,99 %]
CAM-ICU
 Sensitivity (%) 2/6 (33 %)
 95 % CI [4 %,78 %]
 Specificity (%) 69/69 (100 %)
 95 % CI [95 %,100 %]
Test Characteristics in Patients with Dementia at Baseline (N = 26)
3D-CAM
 Sensitivity, (%) 12/13 (92 %)
 95 % CI [64 %,100 %]
 Specificity, (%) 10/13 (77 %)
 95 % CI [46 %,95 %]
CAM-ICU
 Sensitivity, (%) 8/13 (62 %)
 95 % CI [32 %,86 %]
 Specificity (%) 13/13 (100 %)
 95 % CI [75 %,100 %]

MCI mild cognitive impairment, CI confidence interval