Skip to main content
. Author manuscript; available in PMC: 2016 May 1.
Published in final edited form as: Am J Ophthalmol. 2015 Jan 28;159(5):950–7.e2. doi: 10.1016/j.ajo.2015.01.027

Table 1.

Comparison of Linear Distance from the Optic Disc Center to the Macular Center using Color Fundus Photography and Fluorescein Angiography from Patients with Retinopathy of Prematurity.

Case–Eye Distance to Macular Center on Color Fundus Photography (SD), mm Distance to Macular Center on FA (SD), mm Pa
1-OD 5.28 (1.20) 4.96 (0.57) 0.203
1-OS 5.74 (0.91) 6.27 (0.69) 0.355
2-OD 3.07 (0.23) 3.44 (0.34) 0.121
2-OS 3.54 (0.46) 3.40 (0.42) 0.567
3-OD 3.58 (0.46) 4.12 (0.44) 0.240
3-OS 3.29 (0.38) 3.38 (0.32) 0.720
4-OD 3.70 (0.58) 2.90 (0.35) 0.001
4-OS 3.94 (0.87) 2.75 (0.54) <0.001
5-OD 4.10 (0.28) 3.37 (0.24) 0.092
5-OS 4.19 (0.48) 3.16 (0.29) <0.001
6-OD 3.82 (0.12) 3.90 (0.61) 0.750
6-OS 3.24 (0.33) 3.75 (0.68) 0.073
7-OD 4.29 (0.07) 4.29 (1.10) 1.000
7-OS NA NA NA
8-OD 3.54 (0.14) 3.21 (0.35) 0.189
8-OS 3.58 (0.13) 3.68 (0.13) 0.690

SD = Standard Deviation; FA = Fluorescein Angiogram; OD = Oculus Dexter; OS = Oculus Sinister.

a

P value by paired sample t-test.