Table 1.
Observer | Intra-and Inter-Ratter Reliability (Intra class correlation coefficient at 95% confidence interval) | ||||
Variables | F | lower bound | upper bound | Intra-class correlation values | |
Intra-observer, | |||||
Sonographer 1 | Length | 25 | 0.88 | 0.97 | ICC (3, 2, 1) = 0.94 |
Width | 25 | 0.54 | 0.89 | ICC (3, 2, 1) = 0.76 | |
Intra-observer, | |||||
Sonographer 2 | Length | 25 | 0.86 | 0.95 | ICC (3, 2, 1) = 0.92 |
Width | 25 | 0.52 | 0.87 | ICC (3, 2, 1) = 0.74 | |
Intra-observer, | |||||
Sonographer 3 | Length | 25 | 0.89 | 0.98 | ICC (3, 2, 1) = 0.95 |
Width | 25 | 0.55 | 0.90 | ICC (3, 2, 1) = 0.77 | |
Inter-observer, | |||||
All Sonographers | Length | 25 | 0.70 | 0.91 | ICC (3, 2, 1) = 0.83 |
Width | 25 | 0.28 | 0.73 | ICC (3, 2, 1) = 0.52 |
F = Frequency: ICC = Intra class correlation coefficient:
ICC (3, 2, 1) = Intra class correlation coefficient between the first, second, and third measurements obtained by each sonographer, otherwise called intra observer error or variation; and between the first measurements obtained by all the sonographers (inter observer error or variation).