Table V.

Breathing zone and in-duct particle number concentrations

Station Number of Measurements Air Flow (m3 min−1) Breathing Zone In-Duct Conc Reduction Factor (%)

GM (particles cm−3) GSD GM (particles cm−3) GSD
1 2440 12.3 6.03 × 105 2.60 7.75 × 105 2.57 56
2 1761 11.5 2.57 × 106 2.44 1.45 × 106 1.90 36
3 2318 12.3 3.77 × 105 1.41 2.31 × 105 3.30 38