Table 4.
Sensitivity, specificity, and overall agreement of RBPT and stat in comparison to I-ELISA for detection of Brucella antibodies in sheep.
| Test | I-ELISA | Total | Sensitivity (%) | Specificity (%) | Overall agreement (%) | |
|---|---|---|---|---|---|---|
| Positive | Negative | |||||
| RBPT | ||||||
| Positive | 44 | 27 | 71 | 77.19 | 93.69 | 91.75 |
| Negative | 13 | 401 | 414 | |||
| Total | 57 | 428 | 485 | |||
| STAT | ||||||
| Positive | 43 | 27 | 70 | 75.44 | 93.69 | 91.55 |
| Negative | 14 | 401 | 415 | |||
| Total | 57 | 428 | 485 | |||
RBPT=Rose Bengal plate test, STAT=Standard tube agglutination test, I-ELISA=Indirect enzyme-linked immunosorbent assay