Skip to main content
. 2015 Dec 18;291(10):4882–4893. doi: 10.1074/jbc.M115.671172

TABLE 3.

SAXS data collection and derived parameters for CTP1L

Rg, radius of gyration; Dmax, maximal particle dimension; Vp, Porod volume; Vex, particle excluded volume.

Parameters Values
Data collection
    Instrument EMBL X33 beam line (DORIS-III, DESY, Hamburg)
    Beam geometry (mm2) 2.0 × 0.6
    Wavelength (Å) 1.54
    s range (Å−1)a 0.01–0.6
    Exposure time (s) 8 × 15
    Concentration range (mg/ml) 0.2–4.0
    Temperature (K) 293

Structureb
    I(0) (relative) (from p(r)) 88.6 ± 2
    Rg (Å) (from p(r)) 40 ± 1
    I(0) (cm−1) (from Guinier) 85.3 ± 0.3
    Rg (Å) (from Guinier) 37 ± 1
    Dmax (Å) 138
    Porod volume estimate (Å3) 94,520 ± 10,000
    Excluded volume estimate (Å3) 128,000 ± 10,000
    Dry volume calculated from sequence (monomeric/dimeric) (Å3) 40,727/81,453

Molecular mass determination
    I(0) (cm−1) BSA (66,000 Da)
    Mr (from I(0)) 65,160 ± 5000
    Mr (from Porod volume (Vp/1.6)) 59,075 ± 5000
    Mr (from excluded volume (Vex/2)) 64,000 ± 5000
    Calculated monomeric Mr from sequence ∼32,840

a Momentum transfer s = 4πsin(θ)/λ.

b Values reported for merged data sets (CTP1L: 1.0 and 4.0 mg·ml−1).