Skip to main content
. 2016 Mar 3;11(1):37–41. doi: 10.5469/neuroint.2016.11.1.37

Table 2. Morbidity and Mortality between Surgical Clipping and Endovascular Coiling of UIAs in Different Studies.

Studies Mortality Morbidity Total M&M Total Patient No.
Coiling/Clipping (%) Coiling/Clipping
McDonald, et al (2013) 0.5/0.7 4.1/17.0 4.6/17.7 3551/1388
Lawson, et al (2013) 2.2/2.7 2.2/4.8 4.3/7.4 6611/7439
Hwang, et al (2012) 0.6/0.8 5.7/12.4 6.3/13.2 6879/24986
BBrinjikji, et al (2011) 0.6/1.2 4.9/14.0 5.5/15.2 34125/29918
ISUIA (2003) 1.8/1.5 7.3/11.7 9.1/13.2 451/1917
Our study * 0 2 2 202

* = clipping was not compared.