. 2016 Feb 21;3:128–138. doi: 10.1016/j.mex.2016.02.002

Table 1.

Fit results for artificial mixture's noisy spectra, with correct values at top. There are five runs of 0.5% noise since the randomness of the noise affected the fit results. Note also that spectra with 0.1% random error appeared most similar to typical experimental spectra in our research. The spectra with 0.5% error used here would be considered noisy.

Sucrose Glucose Fructose YNB Ethanol Butanol Acetone Acetald. Ac.acid
Exact 10.000 10.000 10.000 1.000 10.000 2.000 2.000 1.000 1.000
#1 9.996 9.999 10.038 0.984 9.984 2.008 1.999 1.014 1.008
#2 9.972 10.017 10.013 1.007 9.973 1.950 1.989 1.019 0.997
#3 9.977 10.056 10.019 0.978 9.938 1.969 2.042 1.035 0.983
#4 9.987 10.017 10.011 0.990 10.026 1.888 1.990 1.026 0.993
#5 10.051 9.958 10.016 0.992 10.003 1.965 2.006 0.980 0.992
avg 9.997 10.009 10.019 0.990 9.985 1.956 2.005 1.015 0.995
σn 0.028 0.032 0.010 0.010 0.030 0.039 0.019 0.019 0.008
erel −0.03% 0.09% 0.19% −1.0% −0.15% −2.2% 0.25% 1.5% −0.50%