Table 1. Magnitudes of the dips (differences between the unmasked and lowest masked thresholds) and slopes of the handles (straight line fits to the data where the pedestal level was >3 dB above that which gave the lowest threshold) for the data shown in Fig 3.
Dip magnitude (dB) | Handle slope | |||
---|---|---|---|---|
0.5 c/deg | 6 c/deg | 0.5 c/deg | 6 c/deg | |
AB | 8.8 | 9.8 | 0.48 | 0.83 |
AR | 7.2 | 2.3 | 0.67 | 0.24 |
DB | 10.4 | 8.2 | 0.91 | 0.53 |
GS | 8.1 | 6.9 | 0.52 | 0.74 |
JZ | 9.4 | 6.1 | 0.74 | 0.69 |
Mean | 8.8 ± 0.5 | 6.7 ± 1.3 | 0.66 ± 0.08 | 0.61 ± 0.10 |