Skip to main content
. 2016 Mar 10;6:23013. doi: 10.1038/srep23013

Table 3. Technical Comparison between different methods and MTT based method.

Method Media requirement per test Time required MIC determination Complexity
Agar dilution Method9 300 ml 24 h Yes More tedious with higher media requirement
Easy MIC Test9 20 ml 24 h Yes Required Easy MIC strips which increased the cost
MTT based Method 300 μl 7 h Yes Very less media required, rapid and simple
Oxacillin Screen Agar9 20 ml 24 h No Cannot detect borderline resistant strains
Oxacillin Disc Diffusion9 20 ml 24 h No Gives false positive results
PCR for mecA14 12–16 h No Set up not available in all laboratories