Skip to main content
. 2015 Nov 6;29(2):254–263. doi: 10.1007/s10278-015-9844-y

Table 5.

Prostate segmentation average results (±standard deviation) using the SRS algorithm with nonrigid registration for 15 patients contoured by 5 users, which includes DSC for the entire volume (%), volume ratio, MAD (mm), MAXD (mm), timesaving (%), and speedup factor. “i” in “Unedited i” represents the number of unedited slices in between any two slices that have been manually contoured

Unedited slices Volume (DSC) (%) Volume (ratio) (%) MAD (mm) MAXD (mm) Timesaving (%) Speedup
Unedited 0 94.35 ± 7.30 91.38 ± 4.46 1.08 ± 0.42 3.39 ± 0.88 −17.79 0.85×
Unedited 1 92.77 ± 7.61 89.58 ± 2.22 1.35 ± 0.43 4.14 ± 0.95 24.22 1.32×
Unedited 2 92.19 ± 11.89 88.57 ± 4.57 1.52 ± 0.40 4.61 ± 0.86 33.87 1.51×
Unedited 3 90.58 ± 15.23 82.86 ± 6.52 2.00 ± 0.46 5.69 ± 1.03 39.00 1.64×
Unedited 4 88.48 ± 16.42 77.56 ± 8.04 2.34 ± 0.56 6.45 ± 1.09 41.59 1.71×
Unedited 5 85.15 ± 17.95 71.59 ± 9.91 2.74 ± 0.68 7.12 ± 1.11 44.45 1.80×