Skip to main content
. Author manuscript; available in PMC: 2017 Sep 1.
Published in final edited form as: Magn Reson Med. 2015 Sep 12;76(3):792–802. doi: 10.1002/mrm.25920

Table 3.

Results of simulations in the human brain. The RMSE in T1 estimates (units of s) are given for each angle set and SNR. RMSE % change is in comparison to optimal angle set for that same number of flip angles.

Nα = 2 Nα = 10
SNR Optimal
angle set
Control angle set Optimal
angle set
10-point repeat 10-point range
RMSE RMSE %
change
RMSE RMSE %
change
RMSE %
change
5 5.94E-1 6.13E-1 +3.20 2.15E-1 2.17E-1 +0.93 3.74E-1 +74.0
10 2.50E-1 2.51E-1 +0.40 1.07E-1 1.07E-1 -- 1.87E-1 +74.8
15 1.62E-1 1.63E-1 +0.62 7.13E-2 7.13E-2 -- 1.24E-1 +73.9
20 1.21E-1 1.21E-1 -- 5.36E-2 5.36E-2 -- 9.33E-2 +74.1
30 8.02E-2 8.00E-2 −0.25 3.57E-2 3.57E-2 -- 6.21E-2 +73.9
40 6.00E-2 6.00E-2 -- 2.68E-2 2.68E-2 -- 4.66E-2 +73.9