Table 3. MICALMO-CH SAXS Data Collection and Scattering refinement parameters.

Data collection parameters
Instrument Beam line SIBYL (LNBL ALS B12.3.1)
q range [Å−1] 0.0128 - 0.3253
Exposure times [sec] 0.5, 1.0, 2.0, 4.0
Concentration range (mg ml−1) 2.0 4.0 7.0
Structural parameters (from P(r))      
I(0) [cm−1] 85.4 (80.1) 216 (199) 413 (398)
Rg (Å) [from P(r)] 31 (31.5) 31.7 (32.4) 32.5(34.1)
Dmax [Å] 114 120 120
Porod’s volume estimate [x 103 Å3] 116(112) 111(103) 107(101)
Dry volume calculated from sequence [Å3] 81884    
Particle-mass estimation/method
Molecular Mass Mr/from I(0); BSA STD [Da] (Δm %)* 55000 (−19.6%)
Molecular Mass Mr /sasmow, q < 0.2533 [Da] (Δm %)* 71500 (4.4%)
Molecular Mass Mr/Mw = (Vc2 Rg−1/1.231)34 51500 53600 55000
Molecular Mass/Size Exc. Chr. [Da] (Δmass %)* 61455 (−10.2%)
Calculated Mw from sequence + FAD [Da] 68425
Final NSD of the ab-initio model (σ) 0.47(0.08)
  Model Rg (Å) Fit SAXS χ2  
Sasref rigid-body solution 30.4 0.98  
Option 1 28.5 1.5  
Option 2 27.5 2.2  
Option 3 24.3 4.2  
Option 4 26.8 2.8  
Software employed
Primary data reduction At the beam-line
Data processing Scatter 2.01c
Ab-initio analysis DAMMIN35
Validation and averaging Damaver (ATSAS)
Rigid-body modeling/refinement Sasref36
Computation of scattering profiles FOXS42
Three dimensional graphic representations Chimera41,44/PyMol45

See also Supplementary Fig. S4. *Difference with respect to the theoretical mass.