Fully quantitative PET data requires an input function (IF) for kinetic modelling that is often acquired via arterial blood sampling. Here, an automatic method to obtain an image-derived input function (IDIF) using MR-PET data is presented and several partial volume correction methods (PVC) are evaluated. Data from three tumour patients were acquired in a 3T MRBrainPET. A bolus of 3MBq/Kg of body weight of 18F-FET was administrated to each subject and a dynamic PET scan (dPET) was performed during 60min. PET data were reconstructed in 23 frames with variable frame length using OP-OSEM (32it, 4sub) including all the corrections. An MPRAGE scan was acquired (TE/TR/TI = 3/2250/900 ms, FA = 9°). Five venous blood samples (VBS) were drawn at the later times later times each 10min. To estimate an IDIF, internal carotid arteries were segmented automatically and these regions were transferred to dPET. After, 4 post reconstruction PVC were applied and the impact of a scaling factor based on a single VBS was also evaluated based on the area under the curve (AUC). All the tested PVC methods resulted in an under estimation of the AUC at later frames which was mitigated after scaling with a VBS at 50 min. In the earlier frames the different PVC resulted in different AUC, which were not possible to validate. The fully automated procedure presented allows one to obtain an IDIF without user interaction. Nevertheless, the initial findings regarding the PVC require further validation with a larger data set.
. 2015 May 18;2(Suppl 1):A27. doi: 10.1186/2197-7364-2-S1-A27
Automatic derivation of an MR-PET image-based input function for quantification of 18F-FET
Nuno Andre da Silva
1,✉, Liliana Caldeira
1, Hans Herzog
1, Lutz Tellmann
1, Christian Filss
1, Karl-Josef Langen
1, Jon Shah
1
Nuno Andre da Silva
1Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
Find articles by Nuno Andre da Silva
Liliana Caldeira
1Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
Find articles by Liliana Caldeira
Hans Herzog
1Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
Find articles by Hans Herzog
Lutz Tellmann
1Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
Find articles by Lutz Tellmann
Christian Filss
1Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
Find articles by Christian Filss
Karl-Josef Langen
1Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
Find articles by Karl-Josef Langen
Jon Shah
1Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
Find articles by Jon Shah
1Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
✉
Corresponding author.
Conference
PSMR 2015: 4th Conference on PET/MR and SPECT/MR
La Biodola, Isola d'Elba, Italy
17-21 May 2015
Collection date 2015 Dec.
© da Silva et al; licensee Springer. 2015
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
PMCID: PMC4798701 PMID: 26956283