Table III.

Dice coefficient comparison of airway clearance between semi-automated and manual segmentation using four axial slices. DC values for all four slices are shown. In column 3 the average of DC for semi-automated and the two manual segmentation is shown. A DC of 0.85 or greater indicates good agreement. First column contains Patient numbers from Table I.

# Manual vs. Manual Manual vs. Automated
1 0.88,0.93,0.95,0.96 0.72,0.86,0.89,0.88
2 0.91,0.84,0.96,0.96 0.74,0.63,0.89,0.91
3 0.98,0.97, 0.98,0.95 0.95,0.93,0.94,0.90
4 0.95,0.96,0.97,0.96 0.79,0.86,0.89,0.83
5 0.87,0.86,0.91,0.91 0.85,0.71,0.81,0.92
6 0.88,0.90,0.95,0.93 0.92,0.93,0.96,0.94
7 0.93,0.93,0.92,0.97 0.87,0.85,0.87,0.94
8 0.93,0.91,0.93,0.96 0.88,0.81,0.83,0.93
9 0.97,0.94,0.91,0.91 0.95,0.92,0.89,0.90
10 0.96,0.96,0.95,0.93 0.94,0.94,0.94,0.91