Skip to main content
. 2016 Mar 22;11(3):e0152014. doi: 10.1371/journal.pone.0152014

Table 2. Parameter changes from 2D planning to 3D simulation in the CL/P subgroups.

Case No. Diagnosis Gender Age (years) Yaw (°) SBC Roll (°) Pitch (°) Mid (mm) Genio (mm) No. of PC
3 LCLP F 17 4 1 5 0 0 0 2
7 LCLP M 20 0 0 0 0 0 0 0
8 LCLP M 18 0 0 0 0 1 0 1
9 LCLP F 17 3 1 3 0 0 0 2
12 LCLP M 19 0 0 0 0 0 0 0
13 LCLP M 20 0 0 0 0 0 0 0
15 LCLP M 18 0 0 0 0 0 0 0
17 LCLP M 19 0 0 0 0 3 0 1
18 LCLP M 18 6 1 0 0 0 3 2
19 LCLP M 19 2.5 0 0 0 4 0 2
20 LCLP F 15 3 1 0 0 5 0 2
22 LCLP M 18 2 0 3 0 0 0 2
24 LCLP M 18 0 0 0 4 1 0 2
26 LCLP M 18 0 0 7.5 0 0 0 1
28 LCLP M 18 12 1 1 0 6.5 6.5 4
30 LCLP M 20 0 0 2 2 0 0 2
5 RCLP F 18 7 1 4 0 0 0 2
6 RCLP M 18 8 1 0 0 3 0 2
11 RCLP F 15 0 0 0 3 0 6 2
23 RCLP F 16 3.5 0 1 0 1 0 3
Mean ±SD (range) UCLP 18.0±1.4 (15–20) 2.6±3.4 (0 to 12) 0.4±0.5 1.3±2.1 (0–7.5) 0.5±1.1 (0–4) 1.2±2.0 (0–6.5) 0.8±2.0 (0–6.5) 1.6±1.0 (0–4)
2 BCLP F 20 2 1 0 0 0 0 2
4 BCLP F 17 2 1 0 0 0 0 1
14 BCLP M 19 6 1 0 0 0 0 1
21 BCLP F 20 0 0 0 0 0 0 0
27 BCLP M 19 7 1 0 0 0 5 2
29 BCLP F 18 2 0 0 0 0 0 1
Mean ±SD (range) BCLP 18.8±1.2 (17–20) 3.2±2.7 (0–7) 0.7±0.5 0 0 0.3±0.8 (0–2) 0.8±2.0 (0–5) 1.2±0.8 (0–2)
1 CP F 32 6 1 0 0 0,5 0 2
10 CP F 17 6 1 2 0 0 0 2
16 CP M 18 2 0 5 0 2,5 3 4
25 CP F 18 5 1 0 0 0 6 2
Mean ±SD (range) CP 21.3±7.2 (17–32) 4.8±1.9 (2–6) 0.8±0.5 1.8±2.4 (0–5) 0 0.8±1.2 (0–2.5) 2.3±2.9 (0–6) 2.5±1.0 (2–4)
Mean ± SD (range) Total 18.6±2.9 (15–32) 3.0±3.1 (0–12) 0.5±0.5 1.1±2.0 (0–7.5) 0.3±1.0 (0–4) 1.0±1.7 (0–6.5) 1.0±2.1 (0–6.5) 1.6±1.0 (0–4)

Abbreviations: LCLP: left cleft lip/palate, RCLP: right cleft lip/palate; UCL/P: unilateral cleft lip/palate; BCLP: bilateral cleft lip/palate; CP: isolated cleft palate; M: male, F: female; Age/y, patient age in years; yaw, absolute yaw correction in degrees, SBC, severe bony collision (1: present, 0: not present); roll, absolute roll correction in degrees; pitch, absolute pitch correction in degrees; Mid, midline correction in millimeters; genio, genioplasty alternation in millimeters; No. of PC, number of parameter changes from 2D to 3D plan; SD, standard deviation.