Skip to main content
. 2015 Dec 31;6(1):7. doi: 10.3390/membranes6010007

Table 4.

Selected performance data for 0.1, 0.14 and 0.2 µm ceramic microfiltration membranes (n. a. = not available).

Membrane TMP CFV Re COD
Removal
Lignin
Removal
Cut-off Channel configuration (bar) (m·s−1) (%) (%)
0.1 µm Mono-channel 2.0 0.25 9549 27.81 20.0
0.1 µm Mono-channel 1.0 0.37 8639 34.09 n. a.
0.1 µm Mono-channel 2.0 5.6 150,000 28.04 42.1
0.1 µm Seven-channel 1.0 0.26 16,370 21.28 31.0
0.14 µm Eight-channel 2.0 0.15 15,302 37.96 n. a.
0.2 µm Seven-channel 2.0 0.51 34,210 23.16 29.2
0.2 µm Nineteen-channel 2.0 0.26 19,108 19.65 28.0
0.2 µm Mono-channel 2.0 0.24 9549 32.83 n. a.
0.2 µm Mono-channel 2.0 0.27 9549 37.51 n. a.
0.2 µm Mono-channel 2.0 0.29 9549 32.81 n. a.