Skip to main content
. 2016 Feb 25;17(3):285. doi: 10.3390/ijms17030285

Table 2.

Description of the antibodies used and their manufacturers, and of immunocytochemistry protocols and detection methods.

Antibody Vendor Epitope Retrieval Primary Antibody (Dilution; Incubation Time) Method of Detection Positive Control
anti-CD4 Dako (Carpinteria, CA, USA) PT-Link, High pH RTU; 20 min Mouse Linker/EnVision/DAB (Dako) lymph node
anti-CD8 Dako PT-Link, High pH RTU; 20 min EnVision/DAB (Dako) lymph node
anti-CD20 Dako PT-Link, High pH RTU; 20 min EnVision/DAB (Dako) lymph node
anti-CD25 Ventana Medical Systems, Inc. (Tucson, AZ, USA) manufacturer’s protocol RTU; manufacturer’s protocol UltraView Universal DAB (Ventana) lymph node
anti-FoxP3 Abcam (Cambridge, UK) PT-Link, Low pH (Dako) 1:100; O/N 4 °C EnVision/DAB (Dako) lymph node

O/N, overnight; DAB, 3,3′-diaminobenzidine; RTU, ready to use.