Table 4.
Merging accuracy on simulated test data sets with ranging error rates from 0–5 %
Accuracy | |||||
---|---|---|---|---|---|
0 % | 1 % | 2 % | 3 % | 5 % | |
Clip&Merge | 99.96 | 67.30 | 40.70 | 32.69 | 30.03 |
FLASH | 97.68 | 66.08 | 40.30 | 32.59 | 30.04 |
AdapterRemoval | 98.13 | 66.54 | 40.39 | 32.57 | 30.02 |
SeqPrep | 97.68 | 44.22 | 33.07 | 30.82 | 30.01 |
The data sets were downloaded from Magoc et al. [20]