Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1984 Nov;52(5):542–548. doi: 10.1136/hrt.52.5.542

Echocardiographic and anatomical correlations in fetal congenital heart disease.

L D Allan, D C Crawford, R H Anderson, M J Tynan
PMCID: PMC481678  PMID: 6498031

Abstract

In a series of 1600 pregnancies 34 cases of congenital heart disease were correctly identified by fetal echocardiography. In each case echocardiographic diagnosis was confirmed by anatomical study. Termination of pregnancy was done electively in 14 cases: in six because of the identification of a cardiac anomaly and in the remaining eight because of multiple congenital anomalies. The remaining 20 fetuses died subsequently owing either to the complexity of congenital heart disease or to associated extracardiac abnormalities, which were present in more than half the fetuses with congenital heart disease. There were eight errors in interpretation of the fetal echocardiogram. The outcome of the pregnancy was not influenced by the error in any case. Fetal echocardiography can predict correctly structural malformations of the heart. The technique is sufficiently reliable to give an accurate prognosis in early pregnancy and provide the basis for alterations in obstetric management.

Full text

PDF
544

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Allan L. D., Tynan M. J., Campbell S., Wilkinson J. L., Anderson R. H. Echocardiographic and anatomical correlates in the fetus. Br Heart J. 1980 Oct;44(4):444–451. doi: 10.1136/hrt.44.4.444. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Allan L. D., Tynan M., Campbell S., Anderson R. H. Identification of congenital cardiac malformations by echocardiography in midtrimester fetus. Br Heart J. 1981 Oct;46(4):358–362. doi: 10.1136/hrt.46.4.358. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Allan L. D., Tynan M., Campbell S., Anderson R. H. Normal fetal cardiac anatomy--a basis for the echocardiographic detection of abnormalities. Prenat Diagn. 1981 Apr;1(2):131–139. doi: 10.1002/pd.1970010208. [DOI] [PubMed] [Google Scholar]
  4. Kleinman C. S., Donnerstein R. L., DeVore G. R., Jaffe C. C., Lynch D. C., Berkowitz R. L., Talner N. S., Hobbins J. C. Fetal echocardiography for evaluation of in utero congestive heart failure. N Engl J Med. 1982 Mar 11;306(10):568–575. doi: 10.1056/NEJM198203113061003. [DOI] [PubMed] [Google Scholar]
  5. Kleinman C. S., Hobbins J. C., Jaffe C. C., Lynch D. C., Talner N. S. Echocardiographic studies of the human fetus: prenatal diagnosis of congenital heart disease and cardiac dysrhythmias. Pediatrics. 1980 Jun;65(6):1059–1067. [PubMed] [Google Scholar]
  6. Rice M. J., Seward J. B., Hagler D. J., Mair D. D., Feldt R. H., Puga F. J., Danielson G. K., Edwards W. D., Tajik A. J. Impact of 2-Dimensional echocardiography on the management of distressed newborns in whom cardiac disease is suspected. Am J Cardiol. 1983 Jan 15;51(2):288–292. doi: 10.1016/s0002-9149(83)80052-6. [DOI] [PubMed] [Google Scholar]
  7. Sahn D. J., Lange L. W., Allen H. D., Goldberg S. J., Anderson C., Giles H., Haber K. Quantitative real-time cross-sectional echocardiography in the developing normal humam fetus and newborn. Circulation. 1980 Sep;62(3):588–597. doi: 10.1161/01.cir.62.3.588. [DOI] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES