Skip to main content
. 2016 Feb 2;594(7):1821–1840. doi: 10.1113/JP271690

Table 2.

Spermine affinities of kainate receptors

Receptor Mean SEM n
GluK2 K d (0 mV) (μm) 5.8 0.3 5
h (mV) −16.0 0.5
k (mV) 20.4 1.0
GluK2/GluK5 K d (0 mV) (μm) 119 30 5
h (mV) −25.9 3.8
k (mV) 69.7 36.0
GluK2+Neto1 K d (0 mV) (μm) 71 13 6
h (mV) −24.0 1.8
k (mV) 43.3 4.3
GluK2+Neto2 K d (0 mV) (μm) 39 2 7
h (mV) −18.5 1.1
k (mV) 48.6 5.3
GluK2/GluK5(P599G) K d (0 mV) (μm) 19 2 4
h (mV) −32.3 3.8
k (mV) 41.4 4.7
GluK2 (300 μm l‐Glu) K d (0 mV) (μm) 21 6 3
h (mV) −24.2 1.9
k (mV) 56.2 14.1
GluK2/GluK5 K d (0 mV) (μm) 170 33 3
(300 μm l‐Glu) h (mV) −51.4 20.0
k (mV) 107.7 47.2
GluK2/GluK5 K d (0 mV) (μm) 81 40 3
(1 mm AMPA) h (mV) −73.4 27.7
k (mV) 56.8 22.9

Affinities were obtained using responses evoked by 1 ms applications of 1 mm l‐Glu in 150 mm NaCl external solution. Values for ‘h’ and ‘k’ indicate the voltage dependency.