QoL expressed in relation to specific valve related concerns, acc. Perchinsky (modif.) [12]

Y (repair) O (repair) Ross M (mechAVR)
n = 36 n = 52 n = 22 n = 29
(%) (%) (%) (%)
1. If you had to do it over again, would you chose the same procedure?
 Yes 92 71 82 72
 I don’t know 6 21 18 21
 No 3 8 0 7
   p value - N.S.
2. After the valve surgery, are you annoyed by the need of follow-up care?
 Never/rarely 89 87 91 69
 Occasionally 11 13 5 31
 Frequently/always 0 0 0 0
   p value   Y vs O vs R - N.S.
        (Y + O + R) vs M - 0,016
3. After the valve surgery, are you annoyed by visiting the doctor frequently?
 Never/rarely 86 73 77 52
 Occasionally 14 27 23 48
 Frequently/always 0 0 0 0
   p value   Y vs O vs R - N.S.
        (Y + O + R) vs M - 0,0088
4. Are you annoyed by frequent blood tests?
 Never/rarely 92 77 86 34
 Occasionally 6 19 9 52
 Frequently/always 3 4 5 14
   p value   Y vs O vs R - N.S.
        (Y + O + R) vs M - 0,00001
5. Are you disturbed the possibility of complications due to your implanted valve?
 Never/rarely 42 58 64 24
 Occasionally 53 42 27 66
 Frequently/always 6 0 9 10
   p value   Y vs O vs R - N.S.
        (Y + O + R) vs M - 0,0079
6. Are you disturbed by the risk of bleeding due to medication?
 Never/rarely 78 73 86 31
 Occasionally 8 27 9 55
 Frequently/always 14 0 5 14
   p value   Y vs O vs R - 0,008
        (Y + O + R) vs M - 0,00001
7. Are you disturbed by the risk of valve failure?
 Never/rarely 53 65 68 55
 Occasionally 39 33 27 38
 Frequently/always 8 2 5 7
   p value - N.S.
8. Are you disturbed by the risk of reoperation?
 Never/rarely 28 60 59 41
 Occasionally 56 31 32 52
 Frequently/always 17 10 9 7
   p value   Y vs O - 0,013