Skip to main content
. 2016 Mar 29;11:657–663. doi: 10.2147/COPD.S98635

Table 3.

Test results before PR according to the severity of COPD and correlations with the 6MST

Test parameters Stage 1 and 2 COPD (n=60), mean ± SD r P-value Stage 3 and 4 COPD (n=31), mean ± SD r P-value
6MST (steps) 502.6±145.9 NA NA 461.1±154.5 NA NA
6MWT (m) 401.1±89.3 0.53 P<0.0001 414.6±81.7 0.55 P<0.005
Power-VT (W) 56.2±24.08 0.43 P<0.005 44.5±20 0.22 NS
VO2-VT (mL/min/kg) 11.5±3.8 0.15 NS 11.1±2.2 0.52 P<0.05
Power-max (W) 92.3±32.3 0.45 P<0.0005 73.9±30 0.44 P<0.05
VO2 max (mL/min/kg) 15.7±5.3 0.29 NS 14.4±3.7 0.62 P<0.005

Abbreviations: PR, pulmonary rehabilitation; 6MST, 6-minute stepper test; 6MWT, 6-minute walk test; VO2-VT, oxygen consumption at ventilatory threshold; VO2 max, oxygen consumption at maximum effort; Power-VT, Power at ventilatory threshold; Power-max, Power at maximum effort; NA, not applicable; NS, not significant.