Skip to main content
. Author manuscript; available in PMC: 2016 Apr 4.
Published in final edited form as: Tissue Eng. 2006 Feb;12(2):413–421. doi: 10.1089/ten.2006.12.413

Table 1.

Comparison Between Basement Membrane Feature Sizes Measured on the Ventricular and Fibrosal Sides of the Heart Valve, Decemet's Membrane in the Human and Canine Cornea,6,9 and Matrigel7

Matrigel Descemet's membrane, human Descemet's membrane, canine Aortic heart valve ventricular basement membrane, porcine Aortic heart valve fibrosal basement membrane, porcine
Elevations (SEM)
    Mean ± SD (nm) 162 ± 52 131 ± 41 115 ± 30 26 ± 13 22 ± 11
    Range (nm) 76-267 76-229 76-153 7-53 4-71
Pore diameter (SEM)
    Mean ± SD (nm) 105 ± 70 38 ± 15 24 ± 8 32 ± 2 28 ± 4
    Range (nm) 26-359 22-87 5-40 12-75 7-98
Fiber diameter (SEM)
    Mean ± SD (nm) 69 ± 35 31 ± 9 15± 7 28 ± 3 30 ± 2
    Range (nm) 8-3 18-59 5-44 6-94 9-66
Pore depth (SEM)
    Mean ± SD (nm) 22 ± 13 22 ± 14
    Range (nm) 4-57 4-89