Skip to main content
. 2016 Mar 30;72(Pt 4):558–575. doi: 10.1107/S2059798316002187

Table 1. Default parameterization in DIALS for scan-static refinement using a single-panel detector.

The vector Inline graphic is defined here for convenience.

Parameterization Model state Parameters Action
Beam s 0 μ1 Rotation about Inline graphic
μ2 Rotation about Inline graphic
ν Set length of s 0 (wavenumber)
Crystal orientation U φ1 Rotation about laboratory Inline graphic
φ2 Rotation about laboratory Inline graphic
φ3 Rotation about laboratory Inline graphic
Crystal unit cell B Inline graphic Set metrical matrix elements
Inline graphic
Inline graphic
Inline graphic
Inline graphic
Inline graphic
Detector d p 0 Set distance along Inline graphic
t 1 Translation along Inline graphic
t 2 Translation along Inline graphic
τ1 Rotation about Inline graphic
τ2 Rotation about Inline graphic
τ3 Rotation about Inline graphic