1 |
Power on-condition, tested for 144 hours |
White |
Maximum degraded sample with 40% lumen depreciation |
Tested stopped after 144 hours as LEDs under On condition reached 70% of its initial lumen output, following the ASISST standards13
|
2 |
Power off-condition, tested for 144 hours |
White |
Maximum degraded sample with 2% lumen depreciation |
3 |
Power on-condition, tested for 356 hours |
Blue |
Maximum degraded sample with 32% lumen depreciation |
Tested stopped after 356 hours as LEDs under On condition reached 70% of its initial lumen output, following the ASISST standards13
|
4 |
Power off-condition, tested for 356 hours |
Blue |
Maximum degraded sample with 13% lumen depreciation |
5 |
Power on-condition, tested for 24 hours |
Blue |
Maximum degraded sample with 13% lumen depreciation |
Samples are chosen from the respective sets to observe the effect of MET test before and after “degradation recovery”. |