Table 3. Conditions and Rationale of the 6 chosen samples for I-V examination and C-SAM spectroscopy.

Unit # Test condition undergone by the test unit White/Blue LEDs Rationale of the choice Remarks
1 Power on-condition, tested for 144 hours White Maximum degraded sample with 40% lumen depreciation Tested stopped after 144 hours as LEDs under On condition reached 70% of its initial lumen output, following the ASISST standards13
2 Power off-condition, tested for 144 hours White Maximum degraded sample with 2% lumen depreciation
3 Power on-condition, tested for 356 hours Blue Maximum degraded sample with 32% lumen depreciation Tested stopped after 356 hours as LEDs under On condition reached 70% of its initial lumen output, following the ASISST standards13
4 Power off-condition, tested for 356 hours Blue Maximum degraded sample with 13% lumen depreciation
5 Power on-condition, tested for 24 hours Blue Maximum degraded sample with 13% lumen depreciation Samples are chosen from the respective sets to observe the effect of MET test before and after “degradation recovery”.