Skip to main content
. 2016 Apr 7;6:24123. doi: 10.1038/srep24123

Table 2. Comparison of optimal An/Ap ratios between 3D simulation and estimation from Equation (14).

Temperature range 300 K–500 K 300 K–800 K 300 K–1000 K
N-type 1 2 3 1 2 3 1
Optimal ratio from simulation 0.90 0.36 0.56 0.77 0.25 0.56 0.66
Optimal ratio from Eq. (14) 0.89 0.35 0.52 0.76 0.25 0.52 0.68
Difference −1.1% −2.8% −7.1% −1.3% 0.0% −7.1% 3.0%