Skip to main content
. 2016 Apr;8(4):646–655. doi: 10.21037/jtd.2016.03.01

Table 5. Accuracy of CT diagnosis (Masaoka-Koga stage).

CT stage Sensitivity Specificity PPV NPV Accuracy
Stage I 42.9% (27/63) 98.7% (74/75) 96.4% (27/28) 67.3% (74/110) 73.2% (101/138)
Stage II 87.5% (28/32) 73.6% (78/106) 50% (28/56) 95.1% (78/82) 76.8% (106/138)
Stage III 90.6% (29/32) 83% (88/106) 61.7% (29/47) 96.7% (88/91) 84.8% (117/138)
Stage IV 63.6% (7/11) 100% (127/127) 100% (7/7) 96.9% (127/131) 97.1% (134/138)

PPV, positive predictive value; NPV, negative predictive value.