Table 2.

Linear regression model of welding fume concentration (ln(mg/m3) on space and ventilation characteristics (n=65).

exp(β)* exp(SE)* p exp(95% CI)*
Intercept 0.51 1.74 0.23 (0.17, 1.54)
Proximity of Breathing Zone to Fume
Away - - - - -
Near 2.62 1.40 0.01 (1.33, 5.16)
In 2.90 1.55 0.02 (1.21, 6.94)
Welding Method
SMAW - - - - -
FCAW (Inner Shield) 4.33 1.79 0.02 (1.35, 13.93)
FCAW (Dual Shield) 5.23 2.20 0.04 (1.07, 25.43)
Oxyacetylene 0.60 2.08 0.48 (0.14, 2.58)
Mixing
No - - - - -
Yes 0.46 1.38 0.02 (0.24, 0.87)
*

Values have been exponentiated to represent the ratio of the breathing zone concentration in the specified group relative to the concentration of the reference group.