Skip to main content
. Author manuscript; available in PMC: 2017 Mar 1.
Published in final edited form as: IEEE/ACM Trans Audio Speech Lang Process. 2015 Dec 23;24(3):483–492. doi: 10.1109/TASLP.2015.2512042

TABLE IV.

Average scores for different systems on −6 and 6 dB IEEE mixtures. Bold indicates best result.

PESQ STOI SNRfw

SSN Cafe Babble Factory SSN Cafe Babble Factory SSN Cafe Babble Factory
Mixture 1.99 1.91 1.96 1.86 0.70 0.65 0.66 0.66 3.10 4.14 4.28 3.38
RM 2.47 2.34 2.53 2.41 0.81 0.75 0.82 0.76 7.46 7.00 8.43 7.13
cRM 2.65 2.48 2.60 2.56 0.82 0.75 0.82 0.77 7.90 7.35 8.41 7.44
PSM 2.58 2.39 2.65 2.47 0.81 0.75 0.83 0.77 8.24 7.50 9.29 7.63
TDR 2.47 2.34 2.39 2.41 0.78 0.73 0.77 0.74 6.66 6.19 7.22 6.18
CMF 2.16 2.15 2.11 2.18 0.74 0.70 0.71 0.72 5.01 5.01 5.47 4.67